Section 4 - Template 10 : Percentile forecasts at a horizontal level or in a horizontal layer in a continuous or non-continuous time interval Preliminary Note: This template was not validated at the time of publication and should be used with caution. Please report any use to WMO Secretariat (World Weather Watch - Basic Systems Department) to assist for validation.
Templates for Section 4
- Template 0
- Template 1
- Template 2
- Template 3
- Template 4
- Template 5
- Template 6
- Template 7
- Template 8
- Template 9
- Template 10
- Template 11
- Template 12
- Template 13
- Template 14
- Template 20
- Template 30
- Template 31
- Template 254
- Template 1000
- Template 1001
- Template 1002
- Template 1100
- Template 1101
- Template 15
- Template 32
- Template 40
- Template 41
- Template 42
- Template 43
- Template 44
- Template 45
- Template 46
- Template 47
- Template 51
- Template 91
- Template 34
- Template 33
- Template 53
- Template 61
- Template 60
More Sections
Octets | Key | Type | Content |
10 | parameterCategory | codetable | Parameter category (see Code Table 4.1) |
11 | parameterNumber | codetable | Parameter number (see Code Table 4.2) |
12 | typeOfGeneratingProcess | codetable | Type of generating process (see Code Table 4.3) |
13 | backgroundProcess | unsigned | Background generating process identifier (defined by originating Center) |
14 | generatingProcessIdentifier | unsigned | Forecast generating process identifier (defined by originating Center) |
15-16 | hoursAfterDataCutoff | unsigned | Hours after reference time of data cut-off (see Note 1) |
17 | minutesAfterDataCutoff | unsigned | Minutes after reference time for data cut-off |
18 | indicatorOfUnitOfTimeRange | codetable | Indicator of unit of time range (see Code Table 4.4) |
19-22 | forecastTime | signed | Forecast time in units defined by previous octet (see Note 2) |
23 | typeOfFirstFixedSurface | codetable | Type of first fixed surface (see Code Table 4.5) |
24 | scaleFactorOfFirstFixedSurface | signed | Scale factor of first fixed surface |
25-28 | scaledValueOfFirstFixedSurface | unsigned | Scaled value of first fixed surface |
29 | typeOfSecondFixedSurface | codetable | Type of second fixed surface (see Code Table 4.5) |
30 | scaleFactorOfSecondFixedSurface | signed | Scale factor of second fixed surface |
31-34 | scaledValueOfSecondFixedSurface | unsigned | Scaled value of second fixed surface |
35 | percentileValue | unsigned | Percentile value (from 100% to 0%) |
36-37 | yearOfEndOfOverallTimeInterval | unsigned | Year of end of overall time interval |
38 | monthOfEndOfOverallTimeInterval | unsigned | Month of end of overall time interval |
39 | dayOfEndOfOverallTimeInterval | unsigned | Day of end of overall time interval |
40 | hourOfEndOfOverallTimeInterval | unsigned | Hour of end of overall time interval |
41 | minuteOfEndOfOverallTimeInterval | unsigned | Minute of end of overall time interval |
42 | secondOfEndOfOverallTimeInterval | unsigned | Second of end of overall time interval |
43 | numberOfTimeRange | unsigned | n - Number of time range specifications describing the time intervals used to calculate the statistically processed field |
44-47 | numberOfMissingInStatisticalProcess | unsigned | Total number of data values missing in statistical process |
48-59 | Specification of the outermost (or only) time range over which statistical processing is done | ||
48 | typeOfStatisticalProcessing | codetable | Statistical process used to calculate the processed field from the field at each time increment during the time range (see Code Table 4.10) |
49 | typeOfTimeIncrement | codetable | Type of time increment between successive fields used in the statistical processing (see Code Table 4.11) |
50 | indicatorOfUnitForTimeRange | codetable | Indicator of unit of time for time range over which statistical processing is done (see Code Table 4.4) |
51-54 | lengthOfTimeRange | unsigned | Length of the time range over which statistical processing is done, in units defined by the previous octet |
55 | indicatorOfUnitForTimeIncrement | codetable | Indicator of unit of time for the increment between the successive fields used (see Code Table 4.4) |
56-59 | timeIncrement | unsigned | Time increment between successive fields, in units defined by the previous octet (see Note 3) |
60-nn | These octets are included only if n>1, where nn = 47 + 12 * n | ||
60-71 | As octets 48-59, next innermost step of processing | ||
72-nn | Additional time range specifications, included in accordance with the value of n. Contents as octets 48 to 59, repeated as necessary. |
( 1) Hours greater than 65534 will be coded as 65534.
( 2) The reference time in section 1 and the forecast time together define the beginning of the overall time interval.
( 3) An increment of zero means that the statistical processing is the result of a continuous (or near continuous) process, not the processing of a number of discrete samples. Examples of such continuous processes are the temperatures measured by analogue maximum and minimum thermometers or thermographs, and the rainfall measured by rain gauge.